PROJECT CASE STUDY

·

#631175

Decontamination and Oil Flush on Steam Turbine Lube Oil System

Industrial Facility

·

Texas

FINAL

ISO Particle Count: 14/12/9

SNAPSHOT

ASSET(S)

Steam Turbine Lube Oil System

YEAR

2026

OBJECTIVE

Remove contamination from the steam turbine lube oil system before recommissioning and verify ISO 16/14/11 or better using particle counts and API 614 screening.

WHAT WE FOUND

The system needed controlled flushing and screening before start-up. Reservoir cleaning before and after flushing prevented residue from carrying into the final fill.

HOW WE DID IT

PROCESS

  1. Stage equipment, install jumper hoses, and set up circulation and filtration.

  2. Extract the reservoir oil and clean the reservoir.

  3. Reintroduce the oil and perform a high-velocity flush with API 614 screening.

  4. Remove the oil and complete final reservoir cleaning.

  5. Refill with Shell Turbo T32, then circulate and purify until the cleanliness criterion is met.

TECHNICAL DETAILS

VERIFICATION METHOD

ISO 4406 Particle Counting and API 614 Screening

FLUID

Shell Turbo T32

RELEVANT SPECIFICATIONS

Condensing steam turbine lube oil system. Initial and final reservoir cleaning, followed by a final fill and purification to the specified cleanliness level.

THE NUMBERS

ISO Particle Count

21/17/14

→

14/12/9

TARGET:

16/14/11 or Better

API 614 Screen Rating

3

→

1

SAFETY

100% Safety Performance

Every Step. Every Reading.

This page is the short version. The full report walks through every step we took, how we verified it, and what the numbers came back at. Customer details are redacted. The data isn’t.

Download Full Technical Report

MORE WORK FROM THE FIELD

ISO Particle Count: 14/11/7

Chemical Clean and Oil Flush on Two Boiler Feedwater Pump Lube Oil Systems

Main NAS Rating: NAS 5

Chemical Clean and Oil Flush on Main and Auxiliary Hydraulic Power Units

ISO Particle Count: 14/12/8

Chemical Clean and Oil Flush on Steam Turbine Generator Lube and Seal Oil Systems