PROJECT CASE STUDY
·
#631175
Decontamination and Oil Flush on Steam Turbine Lube Oil System
Industrial Facility
·
Texas
FINAL
ISO Particle Count: 14/12/9
SNAPSHOT
ASSET(S)
Steam Turbine Lube Oil System
YEAR
2026
OBJECTIVE
WHAT WE FOUND
HOW WE DID IT
PROCESS
Stage equipment, install jumper hoses, and set up circulation and filtration.
Extract the reservoir oil and clean the reservoir.
Reintroduce the oil and perform a high-velocity flush with API 614 screening.
Remove the oil and complete final reservoir cleaning.
Refill with Shell Turbo T32, then circulate and purify until the cleanliness criterion is met.
TECHNICAL DETAILS
VERIFICATION METHOD
ISO 4406 Particle Counting and API 614 Screening
FLUID
Shell Turbo T32
RELEVANT SPECIFICATIONS
Condensing steam turbine lube oil system. Initial and final reservoir cleaning, followed by a final fill and purification to the specified cleanliness level.
THE NUMBERS
ISO Particle Count
21/17/14
→
14/12/9
TARGET:
16/14/11 or Better
API 614 Screen Rating
3
→
1
SAFETY
100% Safety Performance
Every Step. Every Reading.