PROJECT CASE STUDY
·
#631253 / 631254
Chemical Clean and Oil Flush on Two Boiler Feedwater Pump Lube Oil Systems
FINAL
ISO Particle Count: 14/11/7
SNAPSHOT
ASSET(S)
Two Boiler Feedwater Pump Lube Oil Systems
YEAR
2026
OBJECTIVE
WHAT WE FOUND
HOW WE DID IT
PROCESS
Prepare an auxiliary tote and connect both pumps’ tubing into a combined circuit in containment.
Decontaminate both reservoirs and leak-check the combined circuit.
Perform high-velocity chemical cleaning with FF-2020.
Perform a high-velocity oil flush with Chevron GST 32.
Reinstall tubing, fill both reservoirs with filtered oil, and complete the final system flush with the customer’s filtered transfer pump.
TECHNICAL DETAILS
VERIFICATION METHOD
ISO 4406:1999 Particle Counting and API 614 Screening
FLUID
FF-2020 Cleaning Fluid and Chevron GST 32 Operating Oil
FLUID VOLUME
Approximately 12 USG Reservoir Capacity per Pump
RELEVANT SPECIFICATIONS
Two steam turbine-driven boiler feedwater pumps flushed simultaneously through a combined circuit. An auxiliary tote served as the flush vessel and the customer’s filtered transfer pump powered the final system flush.
THE NUMBERS
ISO Particle Count
Not Recorded
→
14/11/7
API 614 Screen Rating
4
→
1
SAFETY
100% Safety Performance
Every Step. Every Reading.
This page is the short version. The full report walks through every step we took, how we verified it, and what the numbers came back at. Customer details are redacted. The data isn’t.
Download Full Technical Report
MORE WORK FROM THE FIELD
Main NAS Rating: NAS 5
Chemical Clean and Oil Flush on Main and Auxiliary Hydraulic Power Units
ISO Particle Count: 14/12/8
Chemical Clean and Oil Flush on Steam Turbine Generator Lube and Seal Oil Systems
System 1 On-Site ISO Count: 12/8/0